Video was sent to us of an RF meter from EPIC campgrounds at the convoy to Canberra showing spikes in frequency. When shown this, we didn’t know enough about RF to understand what it was showing so we consulted external experts to explain if the levels seen on the video were dangerous.
The measuring device appears to be a Trifield Meter Model TF2 set to RF mode (dial to the right). In this mode the device is measuring in milliwatts per square meter (mW/m2) up to 19mW/m2 which can also be seen on the screen. The manufacturers specifications can be found here: https://www.trifield.com/product/trifield-emf-meter/.
In the video the meter can be seen recording levels of up to 19 milliwatts per square meter, spiking only once at the 19.999mW/m2 limit. You’ll notice that the person recording the video mistakenly interprets the reading as spiking at twenty-thousand mW/m2, not twenty (or 19.999) as it actually reads.
The standard for exposure to Radiofrequency fields is given by ARPANSA: https://www.arpansa.gov.au/sites/default/files/rps_s-1.pdf
Schedule 3 on page 30 shows that the maximum exposure to RF frequency in the 6 GHz range (the maximum frequency detection of the meter) is 10 watts per square meter. 1 watt is equal to 1000 milliwatts. This means that the safe exposure to RF at the highest frequency that can be detected by the meter is 10,000 milliwatts per square metre, far above the 19 milliwatts detected by the meter.
You can see the presence of a phone cause spikes in the meter here (at 2:02):
It’s possible that even the person filming the original video with their phone so close to the meter could have been causing some of the meter spiking, in addition to the larger than usual amount of phones and signals in the area due to the thousands of campers at EPIC park.
In either case, the energy levels seen on the meter are 0.19% of the ARPANSA exposure levels. Many people have sent us this video and asked us to investigate, this is what those investigations found.